Pro Breeze
Display / Backlight Failure
Dehumidifier display is blank or very dim, but the unit still runs when plugged in.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed LED/LCD display module, Loose display ribbon cable, Faulty display driver on PCB, Low-voltage power supply issue
How to Fix / Troubleshooting
Safety: Unplug the unit before opening the control panel.
Steps to restore display:
- Check brightness setting: Some models have a dimmer or night mode; ensure it is not engaged.
- Access display PCB: Remove screws securing the top control panel and gently lift it to expose the display PCB and ribbon cables.
- Reseat cables: Carefully disconnect and reconnect the ribbon cable between the display and main PCB.
- Inspect for damage: Look for cracked display glass or burnt components. Replace the display PCB / control panel assembly if damaged.
- Power supply check: If other low-voltage functions are also erratic, the main control PCB’s low-voltage supply may be failing and require replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Display PCB / Control Panel Assembly
Check Price on Amazon
We may earn a commission from links on this page.