Pro Breeze Display / Backlight Failure

Dehumidifier display is blank or very dim, but the unit still runs when plugged in.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed LED/LCD display module, Loose display ribbon cable, Faulty display driver on PCB, Low-voltage power supply issue

How to Fix / Troubleshooting

Safety: Unplug the unit before opening the control panel.

Steps to restore display:

  • Check brightness setting: Some models have a dimmer or night mode; ensure it is not engaged.
  • Access display PCB: Remove screws securing the top control panel and gently lift it to expose the display PCB and ribbon cables.
  • Reseat cables: Carefully disconnect and reconnect the ribbon cable between the display and main PCB.
  • Inspect for damage: Look for cracked display glass or burnt components. Replace the display PCB / control panel assembly if damaged.
  • Power supply check: If other low-voltage functions are also erratic, the main control PCB’s low-voltage supply may be failing and require replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Display PCB / Control Panel Assembly
Check Price on Amazon