Pro Breeze No Power / Input Power Failure

Dehumidifier does not power on at all (no lights, no display).

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Blown internal fuse on main PCB, Faulty power cord, Failed power supply section of main control board, Defective on/off switch or touch panel

How to Fix / Troubleshooting

Safety: Unplug the unit before opening any panels. If you are not comfortable working with mains voltage, seek professional help.

Steps to troubleshoot no power:

  • Check outlet: Test the wall outlet with another appliance. Reset any tripped breakers or GFCI outlets.
  • Inspect power cord: Look for cuts, kinks, or burn marks. If damaged, replace the power cord set with a compatible Pro Breeze part.
  • Access main PCB: Remove the rear or side panel to expose the main control PCB. Locate the input fuse (usually a small glass or ceramic fuse).
  • Test fuse: With a multimeter, check continuity across the fuse. If blown, replace with the same rating. If it blows again immediately, there is a deeper fault in the power supply or compressor circuit.
  • Inspect for burnt components: Look for scorched areas on the PCB. If present, replace the entire main control PCB.
  • Check power switch / touch panel: On models with a mechanical switch, test continuity when switched on. Replace the power switch or touch control panel if it does not function.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Main Control PCB
Check Price on Amazon