E2
Pro Breeze
Evaporator Coil Temperature Sensor Fault
Dehumidifier stops working and shows E2 on the display.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Defective evaporator temperature sensor (coil NTC), Sensor dislodged from evaporator coil, Damaged sensor wiring harness, Failed sensor input circuit on main PCB
How to Fix / Troubleshooting
Safety: Disconnect the dehumidifier from power before opening the cabinet. Sharp metal edges may be present around the coil area; wear cut-resistant gloves.
Steps to resolve E2:
- Reset the unit: Unplug for 5–10 minutes, then reconnect and test. If E2 returns, continue.
- Access the evaporator area: Remove the front or side panels to expose the evaporator coil (the cold aluminum finned coil behind the air intake filter).
- Locate the coil sensor: Find the small NTC sensor clipped or taped directly to the evaporator tubing or fins, with two wires leading back to the main PCB.
- Check sensor placement: Ensure the sensor is firmly attached to the coil. If it has fallen off, re-clip or re-tape it securely to the coil surface.
- Inspect wiring: Look for cuts, pinches, or pulled wires. Verify the connector is fully seated on the PCB.
- Test the sensor: With the unit unplugged, disconnect the sensor and measure resistance with a multimeter. At room temperature, it should show a stable resistance (commonly 5–20 kΩ). Infinite or near-zero resistance indicates a bad sensor.
- Replace if defective: Install a new Pro Breeze evaporator temperature sensor (coil NTC), routing the wires away from the fan blades and reattaching it firmly to the coil.
- If E2 remains: The main control PCB may not be reading the sensor correctly and may need replacement. Consider professional service for PCB diagnosis and replacement.