F1
Pro Breeze Fan Speed Feedback / Tachometer Error

Dehumidifier shows F1 and beeps; unit may still run in a limited mode.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Fan motor tachometer signal missing, Fan motor running at incorrect speed, Loose fan motor connector, Faulty main PCB fan control circuit

How to Fix / Troubleshooting

Safety: Unplug the unit before working near the fan.

Steps to troubleshoot F1:

  • Check for obstructions: Inspect the fan through the grille for any foreign objects. Remove debris with the unit unplugged.
  • Access fan motor: Remove the rear or side panel to expose the fan motor assembly and wiring.
  • Inspect wiring: Ensure the multi-wire connector from the fan motor (often 3–5 wires including tach signal) is fully seated on the PCB.
  • Spin test: Manually spin the fan blade. If it is stiff or noisy, the motor bearings may be failing; replace the motor.
  • Replace fan motor: Install a new Pro Breeze fan motor assembly with tachometer output if the existing motor does not start reliably or runs at erratic speed.
  • PCB diagnosis: If a known-good motor still triggers F1, the main control PCB may not be reading the tach signal correctly and may need replacement.