P3
Pro Breeze Low Temperature Lockout / Anti-Freeze Protection

Dehumidifier shows P3 and will not start the compressor.

Advertisements

Possible Causes

Room temperature below minimum operating range, Evaporator sensor detecting risk of freezing, Faulty evaporator temperature sensor, Control board misinterpreting sensor data

How to Fix / Troubleshooting

Note: P3 often indicates the unit is protecting itself from operating in too cold an environment.

Steps to handle P3:

  • Measure room temperature: Use a thermometer to confirm the room is above the minimum operating temperature listed in the manual (commonly 5–10°C / 41–50°F). If not, move the unit to a warmer space.
  • Allow warm-up: If the unit was stored in a cold area, bring it indoors and let it sit unplugged for 1–2 hours to reach room temperature before use.
  • Check evaporator sensor: If P3 appears even in a warm room, inspect the evaporator temperature sensor for proper attachment and wiring (see E2). Replace if readings are out of range.
  • Control board: If sensor replacement does not clear P3, the main control PCB may be faulty and require replacement.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Evaporator Temperature Sensor (NTC)
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements