EC
Pure Enrichment Refrigerant System Error / Low Refrigerant Protection

Pure Enrichment dehumidifier shows “EC” and stops dehumidifying.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Low refrigerant charge due to leak, Severely blocked condenser coil, Faulty evaporator temperature sensor misreading coil temperature, Failing compressor

How to Fix / Troubleshooting

Safety: Unplug the unit before internal inspection. Do not attempt to open sealed refrigerant lines.

  • Check environment: Ensure the room temperature and humidity are within the unit’s operating range. Very low humidity or temperature can cause EC on some models.
  • Clean airflow path: Remove and clean the air filter. If accessible, gently vacuum dust from the condenser coil and ensure the rear and side vents are unobstructed.
  • Observe coil behavior: With the cover removed (if safe and per manual), plug in and run the unit briefly. If the evaporator coil does not get uniformly cool or only a small section frosts, there may be a refrigerant issue.
  • Sensor check: Verify the evaporator temperature sensor is properly attached and its wiring is intact. A faulty sensor can falsely trigger EC.
  • Professional service: If cleaning and sensor checks do not clear EC, the sealed system likely has a leak or compressor fault. This requires a licensed refrigeration technician; replacement of the unit is often more economical for small dehumidifiers.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Sealed Refrigerant System (Compressor and Coils)
Check Price on Amazon