HI
Pure Enrichment
High Temperature Protection
Pure Enrichment dehumidifier shows “HI” and may shut down or limit operation.
Advertisements
Possible Causes
Room temperature above rated maximum, Blocked condenser airflow causing overheating, Failed ambient temperature sensor reading too high, Faulty control board temperature circuit
How to Fix / Troubleshooting
Safety: Unplug the unit before cleaning or opening panels.
- Check ambient temperature: Ensure the room is not excessively hot (above ~95°F / 35°C). Move the unit to a cooler area if needed.
- Improve ventilation: Provide at least 8–12 inches of clearance around the unit. Do not operate it inside a closet or enclosed space.
- Clean filter and vents: Remove and clean the air filter. Vacuum dust from intake and exhaust grilles.
- Sensor check: If HI appears in a normal-temperature room, inspect the ambient temperature sensor and wiring. Replace the sensor if it is damaged or reading incorrectly.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Ambient Temperature Sensor (NTC Thermistor)
Check Price on Amazon
We may earn a commission from links on this page.