E1
Rowenta
Room Temperature Sensor Error
Dehumidifier displays E1 and stops dehumidifying, fan may still run.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Open or shorted ambient NTC sensor, sensor harness unplugged, damaged sensor wiring, failed sensor on PCB
How to Fix / Troubleshooting
Safety: Unplug the dehumidifier before any internal inspection.
- Power reset: Unplug for 10 minutes, then plug back in and test.
- Check ambient conditions: Ensure the unit is used within the specified temperature range (often 5–35°C). Very low temperatures can cause sensor errors.
- Inspect sensor location: The ambient sensor is usually clipped near the air intake. Make sure it is not covered by dust or blocked by curtains or furniture.
- Internal check: If you can open the front panel, verify the sensor plug is firmly connected to the main PCB and that the wires are not cut or pinched.
- If E1 persists: Replace the ambient temperature sensor assembly or have a technician test and replace it.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Ambient Temperature Sensor
Check Price on Amazon
We may earn a commission from links on this page.