E1
Rowenta Room Temperature Sensor Error

Dehumidifier displays E1 and stops dehumidifying, fan may still run.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open or shorted ambient NTC sensor, sensor harness unplugged, damaged sensor wiring, failed sensor on PCB

How to Fix / Troubleshooting

Safety: Unplug the dehumidifier before any internal inspection.

  • Power reset: Unplug for 10 minutes, then plug back in and test.
  • Check ambient conditions: Ensure the unit is used within the specified temperature range (often 5–35°C). Very low temperatures can cause sensor errors.
  • Inspect sensor location: The ambient sensor is usually clipped near the air intake. Make sure it is not covered by dust or blocked by curtains or furniture.
  • Internal check: If you can open the front panel, verify the sensor plug is firmly connected to the main PCB and that the wires are not cut or pinched.
  • If E1 persists: Replace the ambient temperature sensor assembly or have a technician test and replace it.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Ambient Temperature Sensor
Check Price on Amazon