F5
Rowenta Ultrasonic Nebulizer / Atomizer Fault

Humidifier shows F5 and will not produce mist, even though the fan may run.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed ultrasonic transducer disc, open atomizer driver circuit, water intrusion on atomizer PCB, corroded atomizer wiring

How to Fix / Troubleshooting

Safety: Unplug the unit and empty the water tank before inspection.

  • Check water quality: Use clean, preferably demineralized water. Hard water can cause mineral buildup on the ultrasonic membrane.
  • Clean the nebulizer: Locate the ultrasonic membrane at the bottom of the water basin. Gently clean it with a soft cloth or cotton swab dipped in white vinegar, then wipe with clean water. Do not press hard on the membrane.
  • Dry the basin: Ensure no water has leaked into the electronics compartment beneath the basin. If you see moisture, allow the unit to dry completely for 24 hours before retrying.
  • Inspect for cracks: If the membrane is visibly cracked or detached, the atomizer assembly must be replaced.
  • If F5 persists: The ultrasonic driver circuit on the PCB or the atomizer module is defective. Replacement requires disassembly and should be done by a qualified technician.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Ultrasonic Atomizer Assembly
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements