Russell Hobbs Compressor Locked Rotor or Start Failure

Dehumidifier makes a loud humming noise and then shuts off, little or no water collected

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed compressor start relay/PTC, Seized compressor, Low mains voltage, Faulty main PCB compressor drive

How to Fix / Troubleshooting

Safety: Unplug the unit. The compressor can be very hot; allow it to cool before touching.

Steps:

  • Check supply voltage: Ensure the unit is plugged directly into a suitable wall socket, not an overloaded extension.
  • Test start device: Remove and test or replace the compressor start relay/PTC as described in the E6 procedure.
  • Compressor test: Measure compressor winding resistances and check for shorts to earth. Abnormal readings indicate a failed compressor.
  • PCB relay: If the compressor does not receive power, inspect the main control PCB relay and tracks for damage.
  • Professional replacement: A seized compressor requires replacement by a refrigeration technician.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Compressor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements