Russell Hobbs Compressor Not Engaging / Control or Refrigeration Fault

Dehumidifier powers on but compressor never starts, fan runs continuously

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Humidity set too high or room already dry, Faulty humidity sensor reading too low, Failed compressor relay on main PCB, Defective compressor or start device

How to Fix / Troubleshooting

Safety: Unplug the unit before internal checks.

Steps:

  • Check settings: Set the target humidity to a low value (e.g. 40%) and select continuous mode if available. Allow several minutes for the compressor to start.
  • Verify room humidity: Use a separate hygrometer. If the room is already dry (below setpoint), the compressor will not run.
  • Humidity sensor: If the display shows an unrealistically low humidity, the humidity sensor module may be faulty. Replace it.
  • Listen for relay click: When the compressor should start, listen for a click from the main PCB. No click may indicate a failed relay or PCB.
  • Check compressor start device: Follow the E6 procedure to test the compressor and start relay/PTC. Replace faulty parts.