Russell Hobbs
Poor Dehumidification Performance
Dehumidifier runs but collects very little or no water
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Dirty air filter restricting airflow, Low refrigerant charge, Iced‑up evaporator due to sensor or airflow issues, Room temperature too low for effective operation
How to Fix / Troubleshooting
Safety: Unplug before cleaning or opening panels.
Steps:
- Check environment: Ensure doors and windows are closed. Verify room temperature is within the unit's operating range (typically above 5–10°C).
- Clean filter: Remove and wash the air filter. Dry completely before reinstalling.
- Inspect coils: Remove the cover and check the evaporator coil for heavy dust or ice buildup. Clean dust with a soft brush and vacuum. If iced, allow to fully defrost and then restart.
- Check fan speed: Ensure the fan is running at normal speed. A weak fan motor reduces performance.
- Refrigerant issues: If the compressor runs but the evaporator does not get uniformly cold, the sealed system may be low on refrigerant. This requires a refrigeration technician.