E7
Russell Hobbs Internal Communication Error Between Display PCB and Main Control PCB

Dehumidifier shows E7 and stops operating

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Loose or damaged communication cable between display board and main PCB, Oxidised connectors on control boards, Failed display PCB, Failed main control PCB

How to Fix / Troubleshooting

Safety: Disconnect from mains before opening the control panel or cabinet.

Steps:

  • Power reset: Unplug for 10 minutes and reconnect. If E7 reappears immediately, continue.
  • Access control boards: Remove the front control panel cover to expose the display PCB and the cable leading to the main control PCB.
  • Check cable and connectors: Ensure the ribbon cable or multi‑wire harness is fully seated at both ends. Look for kinks, cuts, or signs of moisture damage.
  • Clean contacts: Gently unplug and replug the connectors several times to wipe oxidation from the pins. Optionally use electronic contact cleaner and allow to dry.
  • Inspect for damage: Look for burnt components or corrosion on either PCB. If present, the affected board should be replaced.
  • Board substitution: If possible, replace the display PCB first (usually cheaper). If E7 persists, replace the main control PCB with the correct Russell Hobbs part number.