Possible Causes

Moisture ingress into touch panel, Damaged keypad membrane, Loose ribbon cable between keypad and display PCB, Faulty display PCB keypad interface

How to Fix / Troubleshooting

Safety: Disconnect from mains before opening the control panel.

Steps:

  • Dry the panel: If the unit was recently cleaned or exposed to high humidity, unplug it and allow the control panel to dry for 24 hours in a warm, dry room.
  • Inspect ribbon cable: Remove the control panel cover and check the flat ribbon cable from the keypad to the display PCB. Ensure it is fully inserted and not damaged.
  • Clean contacts: Gently remove and reinsert the ribbon cable. Use contact cleaner if available.
  • Check for cracks: Examine the keypad membrane or touch panel for physical damage. If cracked or delaminated, replace the keypad / touch panel assembly.
  • Display PCB: If the keypad is good but F1 persists, the display PCB may be faulty and require replacement.