Russell Hobbs
False Empty Tank Detection
Humidifier switches off shortly after turning on, indicator shows tank empty
Advertisements
Possible Causes
Stuck float in base, Faulty water level sensor, Misaligned tank not activating valve, Scale buildup on sensor
How to Fix / Troubleshooting
Safety: Unplug before inspection.
Steps:
- Check tank seating: Ensure the tank is correctly positioned so the valve opens and water flows into the base.
- Clean float and sensor: In the base, locate the float or electronic water level sensor. Clean off any scale or slime with mild detergent or vinegar.
- Test float movement: Make sure the float moves freely up and down. If waterlogged or damaged, replace the float / water level sensor assembly.
- Sensor replacement: If the sensor still reports empty with water present, replace the sensor or the humidifier main PCB depending on design.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Humidifier Water Level Sensor / Float
Check Price on Amazon
We may earn a commission from links on this page.