Sencor Compressor Not Starting

Dehumidifier powers on but compressor never starts; fan runs continuously

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Faulty compressor start relay or PTC, Open compressor winding, Defective main PCB relay, Humidity setpoint higher than room humidity

How to Fix / Troubleshooting

Safety: Unplug the unit before accessing the compressor compartment.

Steps:

  • Check settings: Ensure the target humidity is set lower than the current room humidity and that no timer or continuous fan mode is preventing compressor operation.
  • Listen for clicks: When the unit should start dehumidifying, listen for a relay click and compressor hum. No sound may indicate a control issue.
  • Inspect start device: Remove the compressor terminal cover and inspect the PTC relay and overload protector. Replace if burnt or cracked.
  • Test compressor windings: With power disconnected, measure resistance between compressor terminals and to ground. Replace the compressor (professional service) if windings are open or shorted.
  • Check PCB relay: Inspect the compressor relay on the main PCB for burn marks. If the relay is not energizing despite correct control signals, replace the PCB.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Compressor Start Relay
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements