F0
Sencor
General Sensor Fault / Sensor Out of Range
Humidifier or dehumidifier shows F0 and stops operating
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Any NTC sensor (ambient, evaporator, water temperature) disconnected, Sensor shorted due to moisture, Incorrect sensor type installed, Damaged sensor harness
How to Fix / Troubleshooting
Safety: Unplug the Sencor unit before inspection.
Steps:
- Identify sensors: Refer to the service manual or internal labeling to locate all NTC sensors (ambient, coil, water tank, etc.).
- Check connections: One by one, inspect each sensor connector on the main PCB. Ensure they are firmly seated and not swapped between sockets.
- Inspect for moisture: Look for condensation or water around sensor connectors, especially near the water tank area. Dry thoroughly and apply contact cleaner if needed.
- Resistance check: Measure each sensor's resistance at room temperature. Any sensor reading open circuit or near zero ohms should be replaced.
- Replace faulty sensor: Install the correct Sencor sensor assembly for the specific location and model.
Note: If all sensors test correctly, the main PCB's sensor reading circuit may be defective.