F2
Sencor
Water Temperature Sensor Fault (Ultrasonic Humidifier)
Humidifier shows F2; unit may beep and stop
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Defective NTC sensor in water reservoir, Sensor wire broken or corroded, Connector loose on control PCB, Main PCB sensor circuit failure
How to Fix / Troubleshooting
Safety: Unplug the humidifier and empty the water tank before opening the base.
Steps:
- Locate sensor: In Sencor ultrasonic humidifiers, the water temperature sensor is usually mounted in the base near the ultrasonic transducer or in the water channel.
- Inspect wiring: Check the sensor leads for damage and ensure the connector is firmly attached to the PCB.
- Clean area: Remove any mineral deposits or slime around the sensor using a soft brush and white vinegar, then rinse and dry.
- Measure resistance: Disconnect the sensor and measure its resistance at room temperature. Replace if open, shorted, or far from expected value.
- Replace sensor: Install a new Sencor water temperature NTC sensor if needed.
Note: If F2 persists with a new sensor, the control PCB may need replacement.