LO
Sencor
Low Ambient Temperature Lockout
Display shows LO and dehumidifier does not start dehumidifying
Advertisements
Possible Causes
Room temperature below minimum operating range, Faulty ambient temperature sensor reading too low, Unit placed near cold draft or window
How to Fix / Troubleshooting
Safety: No internal work is required for normal LO operation.
Steps:
- Check room temperature: Use a thermometer to confirm the room is above the minimum temperature specified in the Sencor manual (often 5–7°C).
- Relocate unit: Move the dehumidifier away from cold windows, exterior doors, or unheated spaces.
- Sensor check: If LO appears in a warm room, test the ambient NTC sensor as described under E1 and replace if faulty.
Note: LO is often a normal indication, not a fault, when the room is too cold.