Stadler Form Defrost Control or Airflow Problem

Dehumidifier coils freeze into a solid block of ice

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Defective evaporator temperature sensor, Fan not running at full speed, Very low room temperature, Dirty air filter restricting airflow

How to Fix / Troubleshooting

Safety: Unplug the unit and allow all ice to melt completely before further operation.

  • Check room temperature: Ensure the room is within the recommended operating range. Running a dehumidifier in a cold room will cause icing.
  • Clean filter and coils: Wash the air filter and vacuum dust from the evaporator coil to restore airflow.
  • Verify fan speed: Confirm the fan runs strongly. A weak fan can cause icing; replace the fan motor if it is slow or noisy.
  • Sensor check: Inspect and test the evaporator NTC sensor. A faulty sensor can prevent proper defrost cycles and should be replaced.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Evaporator NTC Sensor
Check Price on Amazon

We may earn a commission from links on this page.