E7
Stadler Form
Water Level Sensor / Float Switch Error (Dehumidifier Tank)
Dehumidifier displays E7 and stops dehumidifying
Advertisements
Possible Causes
Stuck float in water bucket, Faulty float switch or reed sensor, Misaligned bucket, Dirty or scaled water level sensor
How to Fix / Troubleshooting
Safety: Unplug the unit before removing the water tank.
- Check bucket position: Remove the water tank and reinstall it firmly, ensuring it is fully seated and the float arm engages the internal switch correctly.
- Inspect float: On Stadler Form dehumidifiers, the float is usually inside the bucket or in a small chamber. Make sure it moves freely up and down. Clean any slime, scale, or debris with warm soapy water and rinse well.
- Test float switch: With the bucket removed, locate the float switch or magnetic reed sensor inside the unit. Manually actuate it with a non-metallic tool and listen for a click. If the switch does not change state (unit still shows tank full), it may be defective.
- Check wiring: Inspect the wires from the float switch to the control board for damage or loose connectors.
- Replace sensor: If the float switch or reed sensor is faulty, replace it with the correct Stadler Form water level sensor assembly. Ensure the new part is mounted in the same orientation.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Water Level Float Switch
Check Price on Amazon