E3
Sunbeam Humidity Sensor (RH Sensor) Failure

Dehumidifier display shows E3 and compressor will not engage

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed humidity sensor element, Disconnected or loose humidity sensor harness, Contaminated sensor from dust or moisture, Faulty humidity sensing circuit on control board

How to Fix / Troubleshooting

Safety: Unplug the dehumidifier before servicing. Avoid touching the control board with wet hands.

Steps:

  • Power cycle: Unplug for 5 minutes, then reconnect. If E3 returns, continue.
  • Locate humidity sensor: On many Sunbeam dehumidifiers, the humidity sensor is mounted behind the front grille near the air intake or integrated into a small plastic housing with vents, connected to the main PCB by a small multi-wire harness.
  • Visual inspection: Remove the front grille. Look for a small sensor module with slotted openings. Check for dust buildup, corrosion, or broken wires.
  • Clean the sensor: Gently blow off dust with compressed air. If accessible, lightly clean the sensor housing exterior with a dry, soft brush. Do not soak the sensor or use liquid cleaners directly on the sensing element.
  • Check connections: Ensure the humidity sensor plug is fully seated on the control board. Reseat the connector by unplugging and plugging it back in.
  • Functional test: If you have a multimeter and the service manual, you can verify the sensor output voltage or resistance changes when humidity changes (e.g., breathe gently near the intake and watch for change). If there is no change or the reading is out of spec, the sensor is likely bad.
  • Replace the humidity sensor: Install a new humidity sensor assembly specified for your Sunbeam model. Mount it in the same location and orientation to ensure accurate readings.
  • Control board consideration: If a new sensor does not clear E3, the main control board may have a failed humidity sensing circuit and will need replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Humidity Sensor Assembly
Check Price on Amazon

We may earn a commission from links on this page.