E5
Sunbeam
Compressor Overload / Current Protection Fault
Dehumidifier displays E5 and will not dehumidify
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Shorted compressor windings, Failed compressor start relay or PTC, Faulty run capacitor, Defective main control board triac or relay
How to Fix / Troubleshooting
Safety: Unplug the unit. Capacitors can hold a charge; discharge them properly or have a technician handle testing.
Steps:
- Basic reset: Unplug for 10–15 minutes, then plug back in. If E5 reappears immediately when the compressor tries to start, continue.
- Access compressor compartment: Remove the rear or side panel to expose the compressor and electrical box (usually a plastic cover on the side of the compressor).
- Inspect wiring: Look for burnt connectors, melted insulation, or a burnt smell around the compressor terminals and control board.
- Check start components: Remove the compressor terminal cover. Identify the PTC start relay and any run capacitor. Inspect for cracks, bulging, or burn marks.
- Test the capacitor: Using a multimeter with capacitance mode (and after discharging the capacitor), measure its value and compare to the rating printed on the part. Replace if out of tolerance.
- Test compressor windings: With the unit unplugged and wires removed from the compressor terminals, measure resistance between the three pins (C, S, R). Look for reasonable, non-zero values and no shorts to ground. A shorted or open winding indicates a failed compressor.
- Replace faulty parts: If the PTC relay or capacitor is defective, replace with Sunbeam-compatible parts of the same rating. Reassemble and test.
- Control board: If start components and compressor test good but E5 persists, the main control board relay or triac may be faulty and require replacement.
- Note: Compressor replacement is complex and usually not economical on small dehumidifiers; consult a professional.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Compressor Start Relay
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements