F1
Sunbeam Ultrasonic Transducer Fault

Humidifier shows F1 and will not turn on the ultrasonic mist

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed ultrasonic transducer disc, Mineral scaling on transducer surface, Loose transducer wiring, Faulty transducer driver circuit on control board

How to Fix / Troubleshooting

Safety: Unplug the humidifier and empty the tank before working on the base.

Steps:

  • Inspect water chamber: Remove the tank and look at the metal ultrasonic transducer disc in the base. Heavy white scale or discoloration can interfere with operation.
  • Descale the transducer: Pour a small amount of white vinegar into the transducer well, just enough to cover the disc. Let soak for 20–30 minutes. Gently wipe with a soft cloth or cotton swab. Do not use sharp tools that can scratch the disc.
  • Rinse thoroughly: Rinse the base with clean water and dry the exterior. Avoid getting water into the electronics compartment.
  • Check wiring (advanced): If comfortable, remove the bottom cover to access the transducer wiring. Ensure the connector is firmly attached to the control board and that wires are not broken.
  • Test operation: Reassemble, refill the tank, and power on. If F1 clears and mist returns, the issue was scaling.
  • Replace transducer: If F1 persists and there is no mist, the ultrasonic transducer assembly or its driver circuit is likely faulty. Replace the transducer module with a Sunbeam-compatible part. If replacing the module does not help, the main control board may need replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Ultrasonic Transducer
Check Price on Amazon

We may earn a commission from links on this page.