Possible Causes
Extremely high room humidity, Faulty humidity sensor reading maximum, Sensor disconnected from control board, Moisture condensation on sensor
How to Fix / Troubleshooting
Safety: Unplug before accessing internal components.
Steps:
- Verify environment: Use a separate hygrometer to confirm actual room humidity. If humidity is indeed very high, allow the unit to run; HI is informational.
- Check for condensation: If the unit is in a very damp area, condensation can form on the humidity sensor. Turn off the unit and allow it to dry, or move it to a slightly drier area.
- Inspect sensor: If HI is displayed even in a dry room, remove the front grille and locate the humidity sensor. Ensure it is clean, dry, and properly connected.
- Replace sensor: If the sensor is connected but always reads HI, replace the humidity sensor assembly with a Sunbeam-compatible part.