Sunbeam Airflow Without Mist

Humidifier fan runs but there is no visible mist at the outlet

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Ultrasonic transducer not operating, Mist channel disconnected internally, Mist being trapped by closed baffle, Control board not sending power to transducer

How to Fix / Troubleshooting

Safety: Unplug before opening the housing.

Steps:

  • Check mist control: Ensure any adjustable mist output control or directional nozzle is fully open.
  • Transducer check: Look into the water chamber while the unit is on (for a brief moment). If there is no agitation or fine bubbling at the transducer, it may not be operating. Then unplug and proceed.
  • Clean and inspect: Clean the transducer and mist channel as described in earlier entries.
  • Internal ducting: If comfortable, open the housing and verify that the mist duct is properly connected between the water chamber and outlet.
  • Board/transducer replacement: If airflow is good but no mist is generated, replace the ultrasonic transducer. If that fails, the main control board may be defective.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Ultrasonic Transducer
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements