TaoTronics Premature Shutoff / Incorrect Humidity Sensing

Dehumidifier shuts off after a few minutes even though humidity is high

Advertisements

Possible Causes

Humidity sensor reading too low, Sensor located in recirculated air stream, Sensor wiring issue, Control board calibration fault

How to Fix / Troubleshooting

Steps:

  • Verify humidity: Use an external hygrometer to compare room humidity with the dehumidifier's display. A large discrepancy indicates sensor or control issues.
  • Relocate unit: Ensure the unit is not placed in a corner where it re-samples its own dry exhaust air.
  • Inspect humidity sensor: Locate the humidity sensor module and ensure it is positioned to sense room air, not inside the cabinet. Clean dust from its vents.
  • Replace sensor: If readings remain inaccurate, replace the humidity sensor module. If the problem persists, the main control PCB may be miscalibrated and require replacement.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Humidity Sensor Module
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements