E6
TaoTronics
Keypad / Control Panel Communication Error
Dehumidifier shows E6 and will not respond to controls
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Loose ribbon cable between display board and main PCB, Damaged touch control panel, Faulty main control PCB communication circuit, Moisture ingress into control panel
How to Fix / Troubleshooting
Safety: Unplug the dehumidifier before opening the control panel. Avoid static discharge to the electronics; touch a grounded metal object first.
Steps:
- Power reset: Unplug for 5 minutes, then reconnect. If E6 returns immediately, proceed.
- Inspect control panel: Remove the top cover or front bezel to access the touch control/display board. Look for signs of moisture, condensation, or corrosion around the buttons and connectors.
- Check ribbon cable: Ensure the flat ribbon cable or harness between the display board and main PCB is fully seated at both ends. Gently disconnect and reconnect to clean contacts.
- Dry the panel: If moisture is present, carefully dry the area with a lint-free cloth and allow the unit to air dry for several hours in a warm, dry room before retesting.
- Visual inspection: Look for cracked solder joints on the display board, especially at the connector. If you see obvious damage, the board should be replaced.
- Replace faulty board: If reseating cables does not clear E6, replace the TaoTronics control panel/display PCB. If the error persists even with a new panel, the main control PCB is likely defective.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Control Panel / Display PCB
Check Price on Amazon