EC
TaoTronics
Refrigerant Leak / Low Refrigerant Protection
Dehumidifier shows EC and stops dehumidifying
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Low refrigerant charge due to leak in evaporator or condenser, Blocked capillary tube or expansion device, Faulty evaporator temperature sensor misreading, Main PCB detecting abnormal compressor run conditions
How to Fix / Troubleshooting
Safety: Unplug the unit. Do not attempt to cut or open refrigerant lines; this requires certified service.
Steps:
- Check ambient and airflow: Ensure the unit is used within the specified temperature range and that filters and coils are clean. Poor airflow can mimic low refrigerant symptoms.
- Observe coil behavior: With covers removed, run the unit and observe the evaporator coil. If only a small section frosts or cools while the rest stays warm, this often indicates low refrigerant or a restriction.
- Sensor verification: Confirm the evaporator NTC sensor is properly attached and reading correctly (see E2). A bad sensor can falsely trigger EC.
- Professional service: If airflow and sensors are fine and EC persists, the sealed system likely has a leak or charge issue. Contact a professional refrigeration technician; they can leak-test, repair, evacuate, and recharge the system. In many compact dehumidifiers, sealed system repair may not be cost-effective compared to replacement.
Advertisements
Repair Difficulty
Professional Required
5/5
Required Part
Evaporator Coil
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements