F
TaoTronics
Water Level / Float Error (Humidifier)
Humidifier displays F and stops producing mist
Advertisements
Possible Causes
Empty water tank, Misaligned tank, Stuck float in base, Faulty water level sensor or reed switch
How to Fix / Troubleshooting
Safety: Unplug the humidifier before removing the tank.
Steps:
- Refill and reseat tank: Remove the water tank, fill it to the recommended level, and reinstall it carefully so it sits flat and engages any internal valve or pin.
- Check float: In the base of many TaoTronics humidifiers there is a plastic float that rises with water level. Ensure it moves freely and is not stuck by scale or debris. Clean with white vinegar if mineral deposits are present.
- Inspect level sensor: Locate the reed switch or micro-switch near the float. Check for loose wiring or corrosion.
- Replace faulty parts: If the float is damaged or the switch does not change state when the float moves, replace the float assembly or water level switch.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Humidifier Water Level Float Switch
Check Price on Amazon
We may earn a commission from links on this page.