HI
TaoTronics High Humidity Indication / Sensor Out-of-Range

Dehumidifier display shows HI and runs continuously

Advertisements

Possible Causes

Actual room humidity above sensor range, Faulty humidity sensor reading maximum, Sensor blocked by dust or moisture, Loose humidity sensor connector

How to Fix / Troubleshooting

Steps:

  • Confirm humidity: Use a separate hygrometer to check room humidity. If it is extremely high (e.g., >90%), the HI reading may be accurate and the unit will run continuously until humidity drops.
  • Clean sensor: Access the humidity sensor module near the air intake and gently clean its vents with a soft brush or compressed air.
  • Check wiring: Ensure the humidity sensor harness is firmly connected to the main PCB.
  • Replace sensor: If the room humidity is normal but the display remains at HI, replace the humidity sensor module.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Humidity Sensor Module
Check Price on Amazon