Possible Causes

Empty tank or improper seating, Failed ultrasonic transducer, Mineral scale on transducer, Blocked mist outlet

How to Fix / Troubleshooting

Safety: Unplug before cleaning.

Steps:

  • Check water tank: Ensure the tank is filled and properly seated so the valve opens into the base.
  • Descale transducer: Clean the ultrasonic transducer disc with a vinegar solution as described in the E1 humidifier entry.
  • Clean mist outlet: Inspect the mist nozzle and outlet channel for blockages. Clean with a soft brush and rinse.
  • Check fan (for warm/cool mist models with fan): Ensure the small internal fan is running to carry mist out. Replace the humidifier fan motor if not operating.
  • Replace transducer: If cleaning does not restore mist, replace the ultrasonic transducer assembly.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Ultrasonic Transducer Assembly
Check Price on Amazon