E5
TCL Compressor Overload or Current Protection Fault

Dehumidifier shows E5 and will not start the compressor.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Shorted compressor windings, Failed compressor start relay or PTC, Faulty run capacitor, Defective main control board power relay

How to Fix / Troubleshooting

Safety: Unplug the unit. High voltage is present at the compressor terminals. Only work on these components if you are comfortable with electrical testing.

  • Allow cooling: If the unit has been running continuously, let it cool for 30–60 minutes and try again. A tripped overload can reset after cooling.
  • Check power supply: Verify the outlet voltage is within specification and that you are not using an undersized extension cord. Low voltage can cause high current draw.
  • Access compressor compartment: Remove the rear or side panel to expose the compressor and its wiring box.
  • Inspect start components: Remove the compressor cover and inspect the PTC start relay and capacitor for burn marks, cracks, or bulging. Replace any visibly damaged parts with TCL-compatible components.
  • Test capacitor: Use a multimeter with capacitance function to verify the run/start capacitor value matches the rating on its label. Replace if out of tolerance.
  • Check wiring and relays: Inspect wires from the main PCB to the compressor for burns or loose connections. Listen for the compressor relay click when the unit tries to start; if absent, the main board may be faulty.
  • Compressor test (advanced): Measure resistance between compressor terminals (C-R, C-S, R-S). Very low or infinite readings can indicate a shorted or open winding. A failed compressor requires professional replacement.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Compressor Start Relay and Run Capacitor
Check Price on Amazon

We may earn a commission from links on this page.