P3
TCL
Low Ambient Temperature Protection
Dehumidifier shows P3 and will not start the compressor.
Advertisements
Possible Causes
Room temperature below operating range, Faulty ambient temperature sensor reading too low, Control board miscalibration
How to Fix / Troubleshooting
Note: P3 is often a protective indication rather than a hardware failure.
- Verify room temperature: Use a separate thermometer to confirm the room is within the unit’s specified operating range (commonly 41–95°F / 5–35°C). If too cold, move the unit to a warmer area.
- Allow warm-up: If the unit was stored in a cold location, bring it indoors and let it sit unplugged for several hours to reach room temperature before use.
- Sensor check: If the room is warm but P3 persists, inspect the ambient temperature sensor and its wiring. A sensor reading artificially low can trigger P3.
- Replace sensor: Test the ambient sensor resistance and replace it if out of specification. If a new sensor does not resolve P3, the main PCB may be misreading and require replacement.
Advertisements
Repair Difficulty
Easy
2/5
Required Part
Ambient Temperature Sensor (NTC Probe)