P4
TCL Defrost Sensor or Defrost Circuit Error

Dehumidifier displays P4 and stops operation unexpectedly.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open or shorted defrost sensor, Loose sensor connection, Faulty defrost control circuit on main PCB

How to Fix / Troubleshooting

Safety: Unplug the unit before accessing internal components.

  • Reset: Disconnect power for 10 minutes and restart. If P4 returns, continue.
  • Locate defrost sensor: On many TCL models, the defrost sensor is the same as or located near the evaporator temperature sensor, clipped to the coil.
  • Inspect wiring and clip: Ensure the sensor is firmly attached to the coil and the wires are not damaged or pulled loose.
  • Test sensor: Measure resistance at room temperature and compare to TCL’s NTC chart. Replace if open, shorted, or far out of range.
  • Board diagnosis: If a known-good sensor still results in P4, the defrost control circuit on the main PCB is likely defective and the board should be replaced.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Defrost Temperature Sensor
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements