F0
Tosot
General Sensor Error / Sensor Circuit Abnormal
Dehumidifier shows F0 and will not start or stops shortly after starting.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Any of the temperature or humidity sensors open/shorted, Sensor harness unplugged from main PCB, Control board sensor reference circuit failure
How to Fix / Troubleshooting
Safety: Unplug before opening the unit.
Steps:
- Inspect all sensors: Locate the ambient temperature sensor, evaporator/defrost sensor, and humidity sensor. Check that each is firmly connected and not physically damaged.
- Check harness: Follow the multi-wire harness from sensors to the main PCB. Look for pinched or broken wires.
- Reseat connectors: Unplug and replug each sensor connector on the board to ensure good contact.
- Test sensors: Use a multimeter to verify each thermistor’s resistance at room temperature and compare to expected values. Replace any sensor that reads open or shorted.
- Board replacement: If all sensors test good, the main control board may have a failed sensor circuit and will need replacement.
Advertisements
Repair Difficulty
Hard
4/5
Required Part
Main Control Board
Check Price on Amazon