F1
Tosot Water Level Sensor / Float Switch Fault (Humidifier Reservoir)

Humidifier displays F1 and stops or will not start misting.

Advertisements

Possible Causes

Empty or improperly seated water tank, Stuck float in water reservoir, Failed water level sensor or reed switch, Wiring issue between level sensor and control board

How to Fix / Troubleshooting

Safety: Turn off and unplug the humidifier before removing the tank.

Steps:

  • Check water tank: Remove the tank, fill it to the proper level, and reinstall it firmly. Ensure it is aligned with any guide rails or switches.
  • Inspect float: In the base, locate the water level float (often a small plastic piece that rises with water). Make sure it moves freely and is not coated with scale or slime. Clean with mild vinegar solution if needed.
  • Sensor check: Some Tosot humidifiers use a magnetic float and reed switch. Verify the magnet is intact and the float is not waterlogged.
  • Replace sensor: If F1 persists with a full, correctly seated tank and free-moving float, the water level sensor or reed switch may be defective and should be replaced.
Advertisements

Repair Difficulty

Easy 2/5

Required Part

Water Level Float Switch / Reed Switch
Check Price on Amazon

We may earn a commission from links on this page.