F2
Tosot
Ultrasonic Transducer / Nebulizer Fault (Humidifier)
Humidifier shows F2 and stops producing mist; fan may still run.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed ultrasonic transducer disc, Heavy mineral scale on transducer surface, Open or shorted transducer wiring, Driver circuit failure on control board
How to Fix / Troubleshooting
Safety: Unplug the humidifier and empty the water tank before servicing. Do not touch the transducer while powered.
Steps:
- Access transducer: Remove the water tank and any covers to expose the metal ultrasonic transducer disc in the base.
- Clean scale: If there is white mineral buildup, soak the transducer area with a 1:1 vinegar-water solution for 20–30 minutes, then gently wipe with a soft cloth. Do not scratch the disc.
- Inspect wiring: Check the small wires from the transducer to the control board for breaks or corrosion.
- Test operation: Reassemble, refill, and briefly power on. If F2 returns and there is no mist, the transducer or its driver circuit is likely failed.
- Replace transducer module: Install a new ultrasonic transducer assembly compatible with your Tosot humidifier. If the driver circuit on the board is burnt, the main PCB may also need replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Ultrasonic Transducer Assembly
Check Price on Amazon