E3
Trotec
Humidity Sensor (RH Sensor) Fault
Dehumidifier shows E3 and stops dehumidifying; compressor does not start.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed digital humidity sensor module, Moisture-contaminated sensor, Loose or corroded sensor connector, Faulty main PCB humidity input
How to Fix / Troubleshooting
Safety: Unplug the dehumidifier before opening the control panel or front cover.
Steps:
- Check for simple reset: Disconnect power for 10 minutes, then reconnect. If E3 returns immediately, proceed with inspection.
- Locate humidity sensor: On many Trotec units, the RH sensor is mounted behind the front grille or near the air intake, often on a small daughter board or as a small plastic module with vents.
- Inspect for contamination: Dust, lint, or water droplets on the sensor can cause errors. Gently blow off dust with dry compressed air. Do not use liquid cleaners directly on the sensor element.
- Check wiring: Ensure the sensor cable is intact and firmly connected to the main PCB. Look for corrosion on the connector pins and clean with contact cleaner if needed.
- Replace sensor module: If E3 persists and the sensor shows visible damage or corrosion, replace the humidity sensor module with a compatible Trotec part.
- Control board check: If a new sensor does not clear E3, the main PCB may not be reading the sensor correctly and will likely need replacement by a professional.