E7
Trotec Compressor Start Failure / Current Protection

Dehumidifier shows E7 and stops; may occur when trying to start compressor.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Failed compressor start relay or PTC, Shorted compressor winding, Faulty main PCB power relay, Undersized or unstable mains voltage

How to Fix / Troubleshooting

Safety: Unplug the unit. High voltage is present around the compressor and power board; if you are not experienced with electrical work, contact a technician.

Steps:

  • Check mains supply: Ensure the unit is connected to a properly grounded outlet with the correct voltage specified on the rating plate. Avoid extension cords.
  • Listen for compressor: When the unit tries to start, listen for a brief hum followed by a click. Repeated clicking without running suggests start component issues.
  • Inspect start components: Access the compressor terminal cover. Check the start relay/PTC and overload protector for burn marks or loose connections.
  • Test compressor windings: With power disconnected, remove the relay and measure resistance between compressor terminals (C-R, C-S, R-S). Infinite or zero readings indicate a bad compressor.
  • Replace start relay/PTC: If the compressor windings test OK, replace the start relay/PTC with a compatible Trotec part.
  • PCB relay check: If the compressor never receives power, the main PCB relay may be faulty and require board replacement.
Advertisements

Repair Difficulty

Professional Required 5/5

Required Part

Compressor Start Relay/PTC
Check Price on Amazon

We may earn a commission from links on this page.