F1
Trotec
Room Temperature Sensor Fault (Humidifier)
Humidifier shows F1 and will not run the fan or mist generator.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Open/shorted ambient NTC sensor, Damaged sensor cable, Corroded connector, Failed main PCB sensor input
How to Fix / Troubleshooting
Safety: Unplug the humidifier before opening the housing.
Steps:
- Locate sensor: The ambient NTC is usually near the air intake or on a small bracket inside the airflow path.
- Inspect wiring: Check for pinched or broken wires and ensure the connector is firmly attached to the control board.
- Measure resistance: Use a multimeter to verify the sensor has a reasonable resistance at room temperature (not open or shorted).
- Replace sensor: If readings are abnormal, install a new Trotec-compatible NTC sensor.
- PCB check: If a new sensor does not clear F1, the main PCB may be defective and require replacement.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Ambient NTC Temperature Sensor
Check Price on Amazon
We may earn a commission from links on this page.