Possible Causes
Scale buildup on ultrasonic transducer, Low water level, Blocked mist outlet, Failed transducer or driver circuit
How to Fix / Troubleshooting
Safety: Unplug the humidifier and empty the tank before cleaning.
Steps:
- Check water level: Ensure the tank is adequately filled and seated.
- Clean transducer: Use white vinegar and a soft cloth or cotton swab to gently remove mineral deposits from the transducer surface.
- Clear mist outlet: Inspect the mist outlet and any ducts for dust or mold buildup and clean them.
- Use demineralized water: To prevent future scale, use distilled or demineralized water.
- Replace transducer: If cleaning does not restore mist output, replace the ultrasonic transducer module.