F2
Venta Defrost / Coil Temperature Sensor Fault

Venta dehumidifier displays F2 and stops operation

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Open or shorted defrost NTC sensor, Sensor dislodged from evaporator coil, Damaged sensor harness, Faulty defrost circuit on control PCB

How to Fix / Troubleshooting

Safety: Unplug the unit before working near the refrigeration components.

  • Access evaporator: Remove the front or rear cover to expose the evaporator coil. The defrost sensor is typically clipped to the coil tubing.
  • Check mounting: Ensure the sensor is firmly attached to the coil; a loose sensor can misread temperature and trigger F2.
  • Inspect wiring: Look for chafed or broken wires where they pass through metal panels. Reseat the connector on the main PCB.
  • Test sensor: Measure resistance at room temperature and compare with specifications. Replace the defrost NTC sensor if it is open, shorted, or far out of spec.
  • Control board: If F2 persists with a known-good sensor, the defrost control circuit on the main control PCB may need replacement.
Advertisements

Repair Difficulty

Hard 4/5

Required Part

Defrost NTC Sensor
Check Price on Amazon