F3
Venta
Humidity Sensor Fault (Dehumidifier)
Venta dehumidifier shows F3 and will not start the compressor
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Failed humidity sensor module, Sensor contaminated by dust or chemicals, Loose sensor connector, Faulty humidity measurement circuit on PCB
How to Fix / Troubleshooting
Safety: Disconnect from mains before opening the control panel.
- Reset and verify: Unplug for 10 minutes and reconnect. If F3 reappears, continue.
- Locate RH sensor: The humidity sensor is usually near the air intake grille or behind the front panel, connected to the main PCB by a small harness.
- Inspect and clean: Gently remove dust with a soft brush. Do not spray cleaners or water on the sensor element.
- Check connections: Ensure the sensor plug is fully seated on the PCB and that no pins are bent.
- Replace sensor: If F3 persists, install a new humidity sensor module specified for your Venta dehumidifier model.
- PCB replacement: If a new sensor does not resolve the error, the main control PCB may be defective.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Humidity Sensor Module
Check Price on Amazon
We may earn a commission from links on this page.