F5
Venta Compressor / Current Protection Fault

Venta dehumidifier shows F5 and does not collect water

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Locked or failed compressor, Faulty compressor start relay or PTC, Open thermal overload on compressor, Defective main control PCB relay

How to Fix / Troubleshooting

Safety: Unplug the unit. Work on compressor circuits only if you are trained; mains voltage is present.

  • Listen for compressor: When the unit calls for dehumidification, listen for a low humming sound from the compressor. If you hear repeated clicking or buzzing without starting, there may be a start component issue.
  • Check ventilation: Ensure the unit has adequate space around it and is not overheating.
  • Inspect start components: With power disconnected, access the compressor terminal cover. Check the PTC start relay and overload protector for signs of burning or cracking. Replace if damaged.
  • Measure compressor windings: Using a multimeter, check resistance between compressor terminals according to service data. If windings are open or shorted, the compressor is defective.
  • Control board: If the compressor never receives power, the compressor relay on the main control PCB may have failed and require replacement.
  • Sealed system: Compressor replacement and refrigerant handling must be done by a certified refrigeration technician.