F6
Venta
Defrost Protection / Low Temperature Lockout
Venta dehumidifier displays F6 and stops, often with ice buildup on the coil
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Room temperature below operating range, Defective defrost sensor reading too low, Fan not moving enough air across coil, Control board misinterpreting sensor data
How to Fix / Troubleshooting
Safety: Unplug the unit before defrosting ice manually.
- Check room temperature: Ensure the dehumidifier is used within the specified ambient temperature (typically above 5–10°C / 41–50°F). Move it to a warmer room if necessary.
- Defrost the coil: Turn the unit off and allow all ice on the evaporator to melt completely. Place towels to catch water.
- Clean filter and fan: A dirty filter or weak fan can cause icing. Clean the air filter and check that the fan runs at full speed.
- Inspect defrost sensor: Verify that the defrost NTC sensor is properly attached to the evaporator coil and wiring is intact. Replace the defrost NTC sensor if readings are incorrect.
- Persistent F6: If F6 continues in a warm room with a good sensor and airflow, the main control PCB may be misreading temperatures and require replacement.