Vicks
False Bucket Full Detection
Dehumidifier stops frequently and displays that the bucket is full, but the bucket is empty.
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Stuck bucket float, Misaligned bucket, Faulty bucket full switch, Broken float magnet
How to Fix / Troubleshooting
Safety first: Unplug before removing the bucket and accessing switches.
- Re-seat bucket: Remove and reinstall the bucket firmly, ensuring it is fully inserted and level.
- Inspect float: Check the float mechanism inside the bucket or bucket compartment. Ensure it moves freely and is not jammed by dirt or scale.
- Test switch: Locate the bucket full switch and press it manually. If the unit thinks the bucket is full when the switch is not pressed, the switch may be shorted and needs replacement.
- Replace float or switch: If the float magnet is missing or the switch does not change state when actuated, replace the faulty component.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Bucket Full Switch
Check Price on Amazon