E4
Vicks Water Level Sensor / Float Error

Display shows “E4” and the humidifier will not start or shuts down immediately.

Advertisements

Safety Warning

This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.

If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.

Advertisements

Possible Causes

Stuck float in base, Faulty float switch or reed switch, Disconnected float sensor wiring, Mineral buildup around float chamber

How to Fix / Troubleshooting

Safety first: Turn OFF and unplug before removing the tank or base components.

  • Clean float area: Remove the water tank and empty any remaining water from the base. Inspect the float (usually a plastic piece that moves up and down). Soak the base area in a 50/50 vinegar and water solution for 20–30 minutes to dissolve scale, then rinse.
  • Check float movement: Manually move the float up and down. It should move freely and return smoothly. If it sticks, clean again or replace the float assembly.
  • Inspect reed switch: If accessible, locate the small glass reed switch near the float magnet. Ensure its wires are intact and connected to the PCB.
  • Test operation: Reassemble, refill the tank, and power on. If E4 persists, the float switch or reed sensor may need replacement.
Advertisements

Repair Difficulty

Medium 3/5

Required Part

Water Level Float Assembly
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements