Whirlpool
Mechanical Humidistat Failure
Dehumidifier humidistat knob (on mechanical models) does not change operation
Advertisements
Safety Warning
This repair may involve working with high voltage components or water connections. Always unplug the appliance before removing any panels.
If you are not confident in your ability to perform this repair safely, we strongly recommend contacting a professional technician.
Advertisements
Possible Causes
Worn or stuck humidistat contacts, Broken humidistat shaft, Disconnected humidistat wiring, Corroded terminals
How to Fix / Troubleshooting
Safety: Unplug the unit before accessing controls.
Steps to repair mechanical humidistat:
- Access control area: Remove the control panel cover to expose the humidistat.
- Inspect knob and shaft: Ensure the knob is not cracked and that it turns the humidistat shaft. Replace the knob if it is stripped.
- Check wiring: Verify that wires are firmly attached to the humidistat terminals and not corroded.
- Test humidistat: With a meter, check continuity across the contacts while turning the knob. If it does not open/close as expected, replace the humidistat.
Test: After replacement, adjust the knob and confirm that the unit cycles on and off at different humidity settings.
Advertisements
Repair Difficulty
Medium
3/5
Required Part
Mechanical Humidistat
Check Price on Amazon
We may earn a commission from links on this page.
Advertisements