Whirlpool False Bucket Full Detection

Dehumidifier indicates bucket full even when bucket is empty and properly installed

Advertisements

Possible Causes

Stuck or misaligned float, Faulty bucket float switch, Broken bucket tab that actuates switch, Debris interfering with float movement

How to Fix / Troubleshooting

Safety: Unplug the unit before inspecting the bucket mechanism.

Steps to correct false bucket full:

  • Inspect bucket and float: Remove the bucket and locate the float mechanism. Ensure it moves freely and is not jammed by dirt or scale.
  • Check bucket tab: Many Whirlpool buckets have a molded tab that pushes the internal switch. If this tab is broken, the switch will not reset. Replace the bucket if the tab is damaged.
  • Clean float area: Remove any buildup around the float and rinse with warm water. Dry thoroughly.
  • Test float switch: Access the internal float switch and test continuity while moving the float. Replace the switch if it does not change state.

Test: Reinstall the bucket and power on. The bucket full indicator should be off, and the unit should run normally.

Advertisements

Repair Difficulty

Easy 2/5

Required Part

Bucket Float Switch
Check Price on Amazon

We may earn a commission from links on this page.

Advertisements